• OB视讯官网

    Coronal cryosectioning of mouse brains

    Lauren C. Faget, Thomas Hnasko

    Published: 2024-07-16 DOI: 10.17504/protocols.io.q26g713w9gwz/v1
    AI 解读
    浏览 1918

    Disclaimer

    The protocols.io team notes that research involving animals and humans must be conducted according to internationally-accepted standards and should always have prior approval from an Institutional Ethics Committee or Board.

    Abstract

    Cryostat coronal cryosectioning of mouse brain tissue

    Before start

    PFA-perfused, 30% sucrose-cryoprotected, and flash-frozen mouse brains are stored at -80C until cryosectioning

    Steps

    Procedure

    1.

    Retrieve frozen mouse brain stored at -80°C.

    2.

    Place brain in cryostat. Set chamber temperature to -16°C to -20°C. Set brain holder temperature to -20°C. Let brain equilibrate to temperature for at least 0h 20m 0s before sectioning.

    3.

    Insert chuck and blade into cryostat.

    4.

    Apply a drop of OCT on the chuck, and affix brain vertically (olfactory bulbs up).

    5.

    Apply another layer of OCT at the base of the brain, turning the brain-holder with the other hand. Cover the cerebellum and the junction between the cerebellum and cortex with OCT. Allow OCT to freeze solid (~0h 5m 0s).

    6.

    Cut 16 to 30 micron sections. Adjust angle of medio-lateral and ventro-dorsal axis so that sections are free of cutting artifacts, symmetrical, and well-aligned to reference atlas.

    6.1.

    Use of anti-roll plate is optional and can help reduce rolling of sections, but must be carefully adjusted to avoid cutting artifacts.

    6.2.

    For immunohistochemistry we typically cut 30-micron sections for best results. For RNAscope we typically cut 16 to 20-micron sections.

    7.

    Collect free-floating sections in 48-well plate.

    7.1.

    Label your plate lid and base with brain/experiment details using lab marker and/or lab tape.

    7.2.

    Pre-fill wells with 1mL 1X PBS containing 0.01% sodium azide (100mg/L).

    7.3.

    Can use syringe with blunt needle to collect sections after sectioning. Dip needle into PBS and collect section by gently touching it on the side of the section.

    7.4.

    Collect 5 sections per well. Or for experiments that require finer resolution of coordinate can collect sections serially, adding 1 section per well until the end of the plate and start back at well #A1.

    8.

    Use parafilm to seal the lid to the plate (air-tight) and refrigerate at 4°Cuntil further processing.

    推荐阅读

    Nature Protocols
    Protocols IO
    Current Protocols
    扫码咨询